Sterilisator UV

UV-C on the return line. No chemicals in the water.

UV-C light inactivates bacteria and other pathogens as water passes the lamps. Below: what sets the dose, why clear water matters, and what to check as lamps age.

UV-C

lamps

UPVC

housing, fresh and seawater

Made

in our factory

15 days

standard units ship

Apa yang dilakukan

Treats what passes the lamps. Nothing else.

UV-C light damages the genetic material of bacteria, viruses and parasites in the water so they cannot multiply. It adds nothing to the water and leaves no residue. That also means it only treats the water flowing past the lamps at that moment.

UV sterilizer chamber with lamps glowing inside
UV dose

Dose is light × time, after the water takes its share.

UV dose is given in mJ/cm². It depends on lamp output, how long the water stays in the chamber, and how much light the water itself absorbs. Different pathogens need different doses.

Reference
Dose
Sumber

Minimum in Norwegian guidelines for aquaculture water

25 mJ/cm²

4.5-log kill of in a lab test with UVC-LEDAeromonas salmonicida

24 mJ/cm²

Continuous loop treatment in a salmon RAS study

70–80 mJ/cm²

Some organisms, including some viruses and parasites, need far higher doses than bacteria. Tell us the pathogens you are worried about and we size the dose for them.

How it is sized

Flow, water clarity, target dose.

Two UV units with the same lamp power can deliver very different doses in different water. These are the numbers that decide it.

01

Flow through it

Higher flow means less time in front of the lamps, so a lower dose. UV is sized on the peak flow it will carry.

02

Kejernihan air (UVT)

UV transmittance is how much UV light gets through the water. Fine solids, colour and dissolved organics absorb it, which lowers the dose.

03

Target dose

Set by the pathogens you want to control, with margin for the lamps losing output with age.

04

Full flow or side stream

Treating the full return flow protects every tank. A side stream treats part of it each pass and costs less.

Clear water first

Particles shield pathogens from UV light (). That is why UV sits after the drum filter, and why systems with high colour gain the most from ozone ahead of UV: in a USDA study, ozone also raised the water’s UV transmittance ().Aquaculture International, 2018USDA ARS

Running it

Dose falls slowly. Check it on a schedule.

A UV unit can look the same on the day it stops working well. Lamps age, sleeves foul and water clarity changes, all without a visible sign.

Cause
What happens
Periksa

Lamp ageing

Lamps lose UV output with running hours, while still glowing

Running hours against the lamp’s rated life; replace on schedule

Fouled quartz sleeve

Scale and biofilm block light before it reaches the water

Sleeve condition; clean as the manual says

Water clarity worse

More UV absorbed by the water, lower dose

Solids removal; colour; UV transmittance if you measure it

Flow above design

Less contact time, lower dose

Flow through the unit against its rating

Lamp failure

No treatment from that lamp

Lamp status indicators or alarms

UV or ozone?

They do different jobs.

Sterilisasi UV
Generator ozon

Main job

Inactivates pathogens in the flow

Oxidises organics and colour

Adds to water

Nothing

Ozone, dosed and controlled

Typical position

Return line before tanks

Side stream, with a skimmer

Penggunaan tipikal

Most RAS

Dense, marine and shrimp systems

Many systems use both. Ozone ahead of UV clears colour, so the UV works better.

Why buy it from us

UV sized on your water, not just your flow.

A UV unit sized on flow alone can under-dose in coloured water. We size it with the solids removal ahead of it and the pathogens you need to control.

Made in our factory

UV sterilizers are made in our 12,000 m² factory in Boluo, Huizhou.

Fresh and seawater

UPVC housing for freshwater and seawater.

Sized on dose

Flow, water clarity and target pathogens, with lamp ageing allowed for.

15 days

Standard units ship in 15 days. 220, 380 or 110 V.

Spesifikasi

Standard specification.

Item
Sterilisasi UV

Lamp

UV-C

Rumah

UPVC

Air

Fresh and seawater

Posisi

Return line, after solids removal

Dose, lamp power, lamp life

Confirmed per model

Voltage

220, 380 or 110 V

Waktu tunggu

Standard units 15 days

Model flow, lamp count, power and connections are listed in the datasheet. We confirm the model against your flow and water before quoting.

FAQ

UV questions.

Lamps lose output with running hours before they stop glowing. Replace them at the interval in the datasheet for the lamp fitted, not when they fail.

It depends on the pathogens. Published references range from about 25 mJ/cm² as a regulatory minimum to 70–80 mJ/cm² in a salmon RAS study, and some viruses and parasites need more. We size on your target.

UV treats the water passing the lamps. The biofilter bacteria live on the media, not in the water flow.

Yes. Our UV sterilizers use UPVC housing.

Full flow protects every tank on each pass. A side stream costs less but treats only part of the water each pass. Disease risk and budget decide it.

Check lamp hours, sleeve fouling, water clarity and flow. Most under-dosing comes from one of these.

Yes. Send your flow rate and pipe size.

UV for pathogens, ozone for organics and colour. Many systems use both.

Next step

Send your flow and water. We size the UV.

Peak return flow, species, salinity and the pathogens you want to control.