Menara degassing

Vent the CO₂ dense tanks build up.

Fish breathe out CO₂ and the biofilter adds more. A degassing tower strips it from the water as it falls through packing against a flow of air. Below: safe levels, how the tower is sized, and what to check.

CO₂

stripped by air

Packing + fan

set the removal

Made

in our factory

15 days

standard units ship

Mengapa ini penting

CO₂ is the quiet problem.

Fish produce CO₂ as they use oxygen, and so do the bacteria. In a pond, it escapes to the air. In a dense RAS on pure oxygen, very little air touches the water, so CO₂ builds up. Fish under high CO₂ eat and grow worse even when oxygen is fine. In a 15-week trial on pikeperch in RAS, feed conversion went from 1.09 at 5 mg/L CO₂ to 1.82 at 30 mg/L, and the authors recommend staying below 15 mg/L ().Frontiers, pikeperch study

Degassing tower beside indoor RAS fish tanks
Cara kerjanya

Water down, air up, CO₂ out of the building.

Part
Apa yang dilakukan
What to check

Water distribution

Spreads water evenly over the packing at the top

Uneven spread leaves dry packing and lowers removal

Kemasan

Large wet surface where CO₂ leaves the water

Fouled packing loses surface; clean as the manual says

Fan or blower

Moves air up through the packing, against the water

Air flow is the main control on CO₂ removal

Exhaust

Takes CO₂-rich air out of the building

Air vented back into the room raises room CO₂ and cuts removal

Sump

Collects degassed water for the oxygen cones

Air drawn into the pumps from here raises total gas pressure

How it is sized

Packing height and air flow do the work.

How much CO₂ a tower removes depends mainly on how tall the packing is and how much air passes per m³ of water. Feed sets how much CO₂ there is to remove.

01

CO₂ from feed

CO₂ is produced roughly in step with the oxygen the fish and bacteria use, so it follows peak feed.

02

Target in the tanks

Set the CO₂ limit for your species, then the removal needed per pass through the tower.

03

Packing height

Taller packing gives more contact and more removal per pass.

04

Air-to-water ratio

More air per m³ of water removes more CO₂, at the cost of fan energy and room ventilation.

Measured on a commercial farm

At a yellow perch RAS, a tank fed 200 kg a day held about 25 mg/L CO₂ with the stripping fan at full speed and 31 mg/L at reduced speed. Removal across the column was 45% and 24%. The fans had to run near full speed at that feed load ().Summerfelt et al., Bell Aquaculture

Air and energy

The air has to go somewhere.

Turning the fan down saves energy but lets CO₂ rise. At the same farm, the cost of heating the replacement air for the building was far higher than the fan electricity itself (). That makes the exhaust route and the fan control part of the tower design.Bell Aquaculture

Design choice
Effect

Fan with speed control

Air flow follows the feed load, and energy falls when CO₂ is low

Exhaust to outside

CO₂-rich air leaves the building instead of raising room CO₂

Replacement air planned

The building stays at a stable pressure and temperature

CO₂ measured in the water

Fan speed can be set on a real number, not a guess

Running it

When CO₂ rises.

Symptom
Usual cause
Periksa

CO₂ rising after feeding

Air flow too low for the feed load

Fan speed; feed against the design

CO₂ high all the time

Fouled packing, uneven water spread, or exhaust air coming back in

Packing; distribution; where the exhaust goes

pH falling with CO₂

CO₂ forms acid in the water, and alkalinity is low

CO₂ and alkalinity together

Bubbles on fish

Total gas pressure high, often from air drawn into a pump

Pump suction and sump level ()IJRA 2005

Why buy it from us

Degassing sized with the oxygen.

CO₂ removal and oxygen addition are two halves of one gas balance. We size the tower and the cones from the same feed plan.

Made in our factory

Degassing towers are made in our 12,000 m² factory in Boluo, Huizhou.

Sized on feed

Packing and air flow from your peak feed and your species’ CO₂ limit.

Fan sized with it

We size the blower or fan with the tower, with a standby where required.

15 days

Standard units ship in 15 days.

Spesifikasi

What we confirm per project.

Item
Menara degassing

Fungsi

Removes CO₂ by air stripping

Media

High-surface packing

Air supply

Fan or blower, with standby where required

Pengukuran

Flow through the tower and CO₂ load from feed

Dimensions, packing height, air flow

Confirmed per model

Waktu tunggu

Standard units 15 days

Model dimensions, packing, fan power and connections are listed in the datasheet. We confirm the model against your flow and feed before quoting.

FAQ

Degassing questions.

Dense systems and systems on pure oxygen usually do, because little air touches the water. Low-density systems with plenty of aeration may not. We show it in the first layout if yours needs one.

It depends on the species. Research on pikeperch recommends below 15 mg/L, and cold-water species are often given lower limits than warm-water ones. Tell us your species and we set the target.

After the biofilter and before the oxygen cones, so oxygen goes into water that has already lost its CO₂.

Yes. The fan sets how much CO₂ comes out, so we size it with the tower.

Yes, when CO₂ is low. A commercial farm found reduced fan speed let CO₂ rise at high feed, so the fan should follow the feed load or a CO₂ reading.

With a dissolved CO₂ probe, or calculated from pH and alkalinity. Measure in the tanks after feeding, when it is highest.

It lets excess nitrogen escape as well as CO₂. But the usual causes, air leaks into pumps or heated water, have to be fixed at the source.

Next step

Send your feed plan. We size the gas stage.

Peak daily feed, species, flow and building layout. We return tower size, air flow and the exhaust route.